KVH Industries TracVision S2 User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
Azimuth CCW Step
Function: commands a 0.1 deg CCW manual step in azimuth
angle
Command: 4
Argument: none
Response: echoes the command
Elevation UP Step
Function: commands a 0.1 deg UP manual step in elevation
angle
Command: 8
Argument: none
Response: echoes the command
Elevation DOWN Step
Function: commands a 0.1 deg DOWN manual step in elevation
angle
Command: 2
Argument: none
Response: echoes the command
F.3 Operational Commands
Idle Mode
Function: halts active tracking and conical scan, then enters
idle mode
Command: HALT
Argument: none
Response: echoes the command
F-3
Maintenance Port Parser Commands
54-0196 Rev. A
Table F-3
Operational Commands