Set RF Tracking Parameters
Function: sets RF tracking parameter
Command: @SATCONFIG,X,N,F,S,C,ID,P,B,D<cr>
Response: Echoes the input data
Where: @SATCONFIG = directs data to the RF Board
X = satellite location A or B
N = satellite table # (98 & 99 are slots for user-
configured satellites)
F = frequency in MHz (either 00000 or a range from
10700 - 12700)
S = the satellite transponder symbol rate in
Mbit/second (01000 - 30000)
C = the FEC code (e.g., 12, 23, 34, 56, 67, 78)
ID = the satellite network ID in hexidecimal format
(0x####)
P = the LNB polarization (v=vertical, h=horizontal)
B = the LNB down conversion frequency (l=low,
h=high)
D = decoding type (0=test, 1=DSS-A, 2=DSS-B,
3=DVB)
ID Match/Decoded Network ID
Function: report ID match and decoded network ID
Command: @CHECKID
Response: Y,0X####
N,0X####
Where: Y = yes
N = no
0X#### = network ID
G.6 Installation Commands
Set/Report GPS Position
Function: reports or sets default GPS position
Command: GPS<cr>
GPS,XX,D,YYY,E
Response: GPS = XXD YYYE<cr>
GPS: XXD YYYE
Where: XX = latitude (0-90)
D = S (South) or N (North)
YYY = longitude (0-180)
E = E (East) or W (West)