KVH Industries TracVision G4 User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 155
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
Option 1 - Mounting the Sensor to a Horizontal Surface
1. Choose a mounting location based upon the
guidelines in “Choosing the Best Location for the
GyroTrac Sensor” on page 14.
2. Orient the sensor so that the forward reference on
the end cap is pointed forward and is parallel to
the vessel’s fore-and-aft axis (to ±5°). The proper
orientation is illustrated in Figure 2-11.
3. Position the horizontal sensor bracket so that the
sensor module will be properly oriented when
placed in the bracket.
4. Using the holes in the bracket feet as a template,
mark locations for the four mounting screws.
Center punch and drill the four holes with a
1
8"
(3.5 mm) bit. Reposition the bracket over the
mounting holes.
TOWARD BOW
Figure 2-11
Proper Orientation of
the Sensor Module
54-0147
20
TracVision G4 Technical Manual
Page view 24