2.6 Wiring the ADCU
All other wiring for the TracVision system connects at the rear
panel of the ADCU. Included in the GyroTrac kitpack are five
terminal strip connectors with terminal connectors numbered 1
through 60 (see Figure 2-20). You will connect all wires to these
terminal strip connectors first, then you will insert the connectors
into the rear panel of the ADCU.
For the TracVision system to work, you must wire the following
cables to the ADCU:
Antenna Data Cable
Antenna Power Cable (unless you are connecting
antenna power to its own circuit)
GyroTrac Sensor Cable
Vessel Power Cable
IRD Ground Cable(s)
You may also connect other external devices, such as an
autopilot, plotter, remote display, or GPS, to the ADCU.
Figure 2-21 on the following page shows all available connections
to the ADCU.
Installation
54-0147
29
25
33
32
31
3029282726
36
35
34
1
9
87
6
5
4
3
2
12
11
10
13
21
20
19
18
17
16
15
14
2423
22
60
52
5354555657
5859
4950
51
48
40
4142434445
4647
3738
39
Green Label
Blue Label
White Label
Red Label
Yellow Label
Figure 2-20
Terminal Strip Connectors
Connect all wires to the terminal
strip connectors first.
DO NOT
attach the terminal strip connectors
to the ADCU until you have
completed and verified all wiring.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 154 155

Comments to this Manuals

No comments